Bar Graphs, Meters, and Trends 165
1010-1007, Rev. 10
2. Data Sampling Object index: Select from drop-down list which data file to use. Data files are created using
the Data Sampling object.
3. Grid: Displays grid lines on the data table.
a. Enable: Check to enable grid lines.
b. Color: Select color used for grid lines.
c. Column Interval: Enter the number of pixels that separate each column of data.
4. Profile color: Determines the color of the background of the object.
a. Transparent: Enable if you do not want a background color or frame to appear.
b. Frame: Color for the perimeter frame.
c. Background: Color for the background of the object.
5. Text: Select the font and size for all text that appears.
a. Font: Select the Truetype font for the text.
b. Size: Select the size of the font.
6. Time: Enable to display the time when the data was captured by the Data Sampling object.
a. Style: Select from HH:MM:SS, HH:MM, or DD:HH:MM.
b. Color: Determines the color used to display the time.
7. Date: Enable to display the date when the data was captured by the Data Sampling object.
a. Style: Select from MM/DD/YY, DD/MM/YY, DD.MM.YY or YY/MM/DD.
b. Color: Determines the color used to display the date.
8. Sequence no: Enable to display a sequence number of when the data was captured by the Data Sampling
object.
a. Color: Determines the color used to display the sequence number.
9. Time ascending or Time descending: Determines the order in which the data is displayed.
10. History Control: Use to select the target PLC or internal HMI register that is used to determine which data
log file is displayed.
For example, suppose we have data log files that were recorded during a four day period- 20090615.dtl
(June 15th), 20090616.dtl (June 16th), 20090617.dtl (June 17th), and 20090618.dtl (June 18th).
We choose to use internal HMI memory address LW100 for the History Control address. If the value in
LW100 = 0, then the History Data Display object will display the most recent data log record- in this example,
20090618.dtl (June 18th). If the value in LW100 = 1, then 20090617.dtl (June 17th) is displayed, and so on.